For more information about the manufacturer,
please visit the website: www.dewal.com



ABS Type Approval
china classification society

Standard Product Dimensions and Packaging

IMPA Code Width Length Rolls/Box
87 18 01 35mm 10m 28
87 18 02 50mm 10m 20
87 18 04 100mm 10m 12
87 18 03 140mm 10m 7
87 18 07 250mm 10m 4
87 18 05 500mm 10m 2


Technical
Data
Test
Method
Results Metric
Results
Backing
Material
Glass/Foil
Backing
Thickness
0.0035
in.
0.009
cm
Adhesive
System
Silicone
Adhesive
Thickness
0.0035
in.
0.009
cm
Adhesion ASTM-D
1000
67
oz./in.
747.79
g/cm
Elongation 7%
Max.
Operating
Temp
500°F 260°C
Maximum
Pressure
300psi 20 bars
Product Description

Anti-Splash Tape by DeWal is constructed of an aluminum/glass cloth laminate coated with a high temperature silicone adhesive. The tape is designed to prevent and contain hot oils from coming in contact with hot surfaces and to prevent possible fires within engine room compartments. DeWal Anti-Splash Tape is provided ‘self-wound’ -NO LINER-, that is with no liner for ease of use during the installation process. A linered product is available upon request.

Applications
  • Fuel oil injection pipes, fuel oil service pipes, fuel oil valve cooling oil pipes attached to diesel engines
  • Lube oil service pipes and hydraulic oil pipes attached to diesel engines
  • Flammable oil pipes
  • Flammable oil pump and strainer
  • Fuel oil heater

The preceding areas of fire risk should be protected from the following sources of ignition:

  • Exhaust gas pipe
  • Steam pipe
  • Turbo charger
  • Electrical equipment
  • Boiler, thermal oil heater, incinerator
Application Instruction
  1. All surfaces to be protected need to be clean and free of oil.
  2. Select the DeWal Tape format applicable to your installation, and, rough measure quantity required. Cut with scissors to size as follows:
  3. For Pipes and Joints
    Use DeWal Tape and allow overlap of 50% each turn.

    For Valves, Flanges, and other irregular shaped equipment
    Use DeWal Tape and cut one piece:

    • Length to wrap 2 layers thick around surface to be protected.
    • Width to be enough to completely cover bolts and overlap onto connecting pipe at least 100 mm (4″).
    • Special care must be taken where a device such as a valve is connected to the pipe being wrapped. In this case, the DeWal Tape must be wrapped around the attached device as well as the pipe.
    • When using DeWal Sheet, apply DeWal Tape on top of the sheet overlapping 50% to secure the DeWal Sheet.

  4. Important Recommendation: When applying DeWal Tape, be sure to wrap loosely to allow free flow of oil leak. DO NOT WRAP TIGHTLY.
  5. When applying DeWal Sheet or Tape, apply a little at the time. Wrap snugly (not too tight) around pipe or joint in the likely direction of an oil spray leak. DeWal Sheet or Tape should be continued to a point where any potential leaks would occur safely away from hot surfaces that could cause combustion.
  6. For maintenance and repairs, DeWal Tape can be removed by cutting with a knife, or tearing with pliers. DeWal Tape cannot be reused once removed.
  7. Important Note: Periodic inspections must be carried out in areas applied with DeWal Tape. Unravelling, curling, loosening or cracking indicates tape on the applied area must be replaced.
Downloads

Technical Data Sheet  |  Download PDF
Type Approval Certificate  |   Lloyd's Register (PDF)_1  |   Lloyd's Register (PDF)_2  |   Lloyd's Register (PDF)_3  |   DNV-GL (PDF)  |   ABS (PDF)  |   China Classification Society (PDF)
Marine Design Appraisal Document  |  Download PDF